Page 45 - Shashwat - Restoring Green Economy
P. 45

43




             conducted by Mumbai Metropolitan   Factors Affecting           major reason that contributed to such
             Region Development Authority                                   a scenario was the presence of highly
             (MMRDA) with Doctors for        the Living                     dense and compact buildings.
             You Association stated that the   Conditions
             occurrence of tuberculosis was                                 Improper Planning: This has
                                             Density: The gross density for   affected the performance of the SRA
             strongly associated with the built
                                             residents is nowhere higher than   buildings. The compact arrangement
             environment of the houses and
                                             1700 persons/hectare in Mumbai.   of buildings in case of group
             the layout of the buildings. The
                                             This is despite not having enough   developments has led to inadequate
             outbreak of the disease was found
                                             land set aside for amenities and open   natural light and ventilation. The
             to be least in those colonies with a
                                             spaces. Such a high demand created   distance between two buildings
             better built environment and layout
                                             the need for high-rise SRA buildings.   should be sufficient to allow enough
             characteristics.
                                             According to the survey conducted by   light to penetrate deep into the
             This article argues that efficient   Doctor for You Association, the SRA   ground floor for better air movement
             daylighting and ventilation strategies   buildings lacked in performance and   in the surroundings.
             are important factors that affect   failed to meet the standard of living
             human health and living conditions   in terms of lighting and ventilation   Continuous ventilation in the kitchen
             within a particular space.      when packed close to each other. The   area is a basic requirement of efficient



                                                                                                    Lux
               Before                                                                               300+
                                        Toilet                         Toilet                       273
                          Kitchen                                                   Kitchen         246
                                                                                                    219
                                                                                                    192
                                                                                                    165
                                                                                                    138
                                                                                                    111
                                Living                                      Living                  84
                                                                                                    57
                  CORRIDOR SIDE                     EXTERIOR SIDE  CORRIDOR SIDE                EXTERIOR SIDE  30









                                Bedroom 1                                    Bedroom 1






               Space  SP 41  Achieved  The window opening of Kitchen is provided in corridor, due   Space  SP 41  Achieved
                                     to which it does not receive the requirement amount of
               Living  50     220    daylight and ven la on. On flipping the posi on of Kitchen   Living  50  245
               Bed 1   152    265    with Toilet, the Kitchen can have direct opening and a duct   Bed 1  152  265
              Kitchen  200    120    can be designed for Toilet Ven la on. This results in be er   Kitchen  200  300+
                                     dayligh ng and natural ven la on for Kitchen.


                » Figure 1: Daylight simulation for proper planning of inner spaces
   40   41   42   43   44   45   46   47   48   49   50