                                46




             Solar reflectors: These can be used   an effective alternative. The area of   be large openings in the building’s
             to increase the lighting by helping it   openings on the exterior surface or   volume to ensure proper wind flow in
             penetrate into those spaces which   the surface facing the internal chowk   and around the buildings. This will
             are shaded due to external factors. In   increases due to the provision of   streamline the wind flow (Figure 6)
             the gaps between two SRA buildings,   grills. This allows better light to enter   and create an opening for the air to
             which are closely packed, these   the building inner volume.   flow inside the building evenly.
             reflectors can be used to light up
             the existing SRA buildings (Figure   Through and through refuge: The
             5) if they do not meet the sufficient   refuge floor was mostly found to be   Conclusion
             amount of daylighting levels. With   open on one side only. By making the   SRA buildings intend to serve the
             these reflectors installed on top of   refuge floor through and through, the   purpose of providing slum dwellers
             the building, the ventilation shafts   rate of wind flow can be improved.   with housing and better living
             can also be lit to ensure that adequate   The wind flow was found to be   conditions. But in the current
             light reaches the corridors and   more streamlined with an improved   scenario, the quality of the SRA
             corners deep down the shafts.   quality too (Figure 6).        settlements needs reconsideration.

             Grills for parapet: The provision of   Large openings: Continuously   The existing buildings, which are
                                                                            unable to meet the quality standards,
             grills or punctured designs in place   packed buildings tend to obstruct the   should be revived with mitigation
             of solid handrails was found to be   movement of the wind. There should


                                          May 21  April 21
                                                    March 21                              Solar Reflectors
                                        June 21             Addi on of Solar
                                                    December 21  reflectors on terrace to
                                                            reflect sunlight on lower
                                                            floors
                                                            Reflected light through
                                                            solar reflectors
                                                            Reflected Light through
                                                            Refuge Floors


                                                            Reflected Light through
                                                            Refuge Floors
                                                            Shaded Area
                                                            Increase in Reflected
                                                            Light through white/light
                                                            color paint & High
                                                            Albedo Road.
                 SECTION - Showing light  SECTION - Showing light                    ELEVATION
               penetra on for Base Design.  penetra on for Proposed Design.                       25000Lux
                                                                        Concave Mirrors  Convex   22500
                                                                                    Mirrors
                                                                 Convex                           20000
                                                                 Mirror
                                                                                                  17500
                                                                                                  15000
                                                                                                  12500
                                                                                                  10000
                                                                                                  7500
                                                                                                  5000
                                                                                                  2500
                 Illumina on analysis                                  SCHEMATIC SECTION
                » Figure 5: Solar reflectors between two closely packed towers
   43   44   45   46   47   48   49   50   51   52   53