                                                                            and air circulation inside the space.
                                        North
                                                                            Cross-ventilation ensures that the
                                                                            building is naturally ventilated,
              Wind flow                                                      thereby improving the overall ACH.
                                                                Sun Path    At least, ventilator provision must be
                                                                            given to improve the movement of air
                      West                             East                 within the space as shown in Figure 4.

                                                                            The introduction of jaali over windows
                                                                            could be an efficient feature to reduce
                                                                            the incoming air temperature using
                                                                            the the funnel effect. The addition of
                                        South                               an internal chowk inside the building
                                                                            volume increases the cross-ventilation
                » Figure 3: Building orientation                            rate of the building.

                                                                            Wing walls: These are projections
             Design: The orientation of the   proper ventilation inside the space.   on the exterior wall to effectively
             building’s longer façade along the   Taking into consideration the surface   enhance the natural ventilation.
             north-south direction will reduce the   reflectance of the interior surfaces   When properly positioned, the wing
             heat gain inside the buildings (Figure   and the visual light transmittance   walls produce high pressure and
             3). Thus, the total radiation received   (VLT) of the window’s glazing will   low-pressure regions on the inlet and
             by the building mass will be reduced.   ensure the deep penetration of the   outlet windows, respectively.
             The wind flow will be in a near-  light into the inner spaces. According   Hence, this helps to draw in more
             parallel range with the building’s   to the previously discussed norms,   wind even during low external wind
             longer axis and will increase the   maintaining a proper distance   velocity conditions.
             ventilation rate inside the building   between two buildings will guarantee
             volume.                         enough daylight availability at the   Light wells: These are external
                                             lower floors and better air movement.  spaces provided within the volume of
             The spatial design should be                                   a building to allow light to reach the
             efficiently planned by the architects   Cross-ventilation: This should be   darker or unventilated areas. Light
             in order to meet the building   taken care of by providing windows   wells are commonly characterized
             standards. Avoiding rooms and   on either side of the rooms which   by highly reflective surfaces.
             spaces without adequate openings   continues to be a lacking area   The provision of light wells will
             for daylight and ventilation is the best   within SRA schemes. SRA buildings   significantly improve the quality of
             strategy. Maximizing the window   are mostly designed with one-  lighting and ventilation inside the
             openings for better intake of sunlight   sided ventilation. This affects the   building space, thus illuminating the
             and openable areas will ensure   ventilation rate of the building space   darker spaces inside the building.



                              Cross Ven la on                              Single Sided Ven la on

                                  VENT                                Without
                                                                      VENT
               WINDOW                                                                          WINDOW

                           LIVING       CORRIDOR                     CORRIDOR         LIVING
                                                    INTERNAL CHOWK


                » Figure 4: Cross-ventilation and single-sided ventilation